Full-time line surge protect. Wide input voltage window. Line interactive design providing high reliability. Self Diagnostic (intelligent battery management) Input over voltage protection. Regulating output voltage. DB-9 communication interface. Peak current Limit protection. Output short circuit protection. UPS Uninterruptible Power Supply.
Back ups for your workstation in the event of power failure. Intelligent battery management for self tests, on battery, low battery, constant voltage/current recharging, battery discharge protection. AVR Automatic Voltage Regulator. Wide AC input voltage and regulates the output voltage to ensure the workstations are working in normal, without using the batteries. Stabilizes the high input voltage to safeguard the equipment. LINE interactive design providing greatest efficiency and reliability, which is an advanced design to combine the OFF-LINE UPS with ON-LINE AVR. LSP Line Surge Protection Full time AC line surge protect to the equipment. Filter and noise isolation can avoid the data files was missed in any possibilities. INTERFACE Communication Interface Port. The communication interface port on P series providing all major operating systems an automatic, unattended shutdown securely.
CELL GUARD - the best guard for your PC and Workstation.
Specification:
MODEL P600R
INPUT Capacity 600VA
Range 170 ~ 260 VAC, 85 ~ 130VAC
Frequency 50Hz ¡Ó 5%, 60Hz ¡Ó 5%
Voltage 220V, 110V
Regulator with Automatically Voltage Regulation
Transfer Time < 2ms
PROTECTION Spike Protection 40j/ms
Unit Input Fuse Protection
Noise Modem/Fax Noise Filter
Short
Circuit LINE Fuse Protection
Short
Circuit INVERTER Electrical & Active Protection
BATTERY Type Sealed, Maintenance Free Lead Acid
Recharge Time 8 hours
Protection Auto-protection,
Intelligent Charge Constant
Voltage/Constant Current
ALARM Back-up Time
(per PC) 10 to 30 minutes
Battery Back-up Beeping sound per 4 sec
Battery Low Beeping sound per 1 sec
Battery Exhaust Continuous beeping
Over Load Continuous beeping
PHYSICAL LED Display AVR Green Light : AVR & CHARGING
Back up Yellow Light : Inverter output from battery
Fault Red Light: Over load, battery exhausted and cut-off.
Size (L x W X H ) 124 x 350 x 170mm
Weight 7kgs
ENIVRONMENT Operating Temperature 0¢XC to 40¢XC ; 32¢XF to 104¢XF
Operating Humidity 0 to 90%
NOISE Distance 1 meter from UPS < 35db
CUMMUNICATION
INTERFACE PORT The communication interface port on P600R/P1000R
providing all major operating systems an automatic
unattended shutdown securely